Monday, August 31, 2009

WARG Telemetry update

Ive got my hands on some CSLA2CF hall effect current sensors.

They look to be ideal for the job we want them to do, onsite power monitoring

These are a three pin device with the following characteristics:

Vs 6-12
Is 20mA max
I(sensed) 125A max
Voffset Vcc/2
Sensitivity 19.6mV/NI @ 8VDC
temp offset 0.02% / degC

I believe this means that with a supply voltage of 12V and the wire passing through the toroid without a turn (ie N=1) a current of 0A will produce an output of 6V
a current of 5A will produce 6V+5x19.6mV =6.098V.

Our KPC9612+ telemetry channels want a 0-5V reading

That pretty much sums up the interfacing requirements. looks like our 2:1 voltage divider will come into play again.

I'll be posting some pix and diagrams soon. stay tuned!

Sunday, August 30, 2009

VK6 APRS Frequencies and Path settings

We are working on making the "paradigm" system standard here in Western Australia.
We recommend

via WIDE1-1,WIDE2-1

for 145.175 MHz. This gives you two hops to VK6HGR's igate in Beechboro.

If you are on 145.825 MHz the best path is

via ARISS,SGATE

myself and VK6HGR are currently running sgates

if you are doing HF aprs at 300baud the frequency to use is 10.1476 MHz USB and the path is

via GATE

VK6UZ is running a HFGATE in Bedfordale

Welcome to the home of APRS in Perth

Welcome to the VK6FUN APRS blog.

This website is intended to become a home for information about how to get the most from APRS here in Western Australia.
We'll be discussing mainly projects and ideas speciifically related to VK6

Post your comments flames suggestions plugs, rants etc here, as long as it's on topic and not personal.

cheers